Microfocus X-ray Source G-511 Series
This radiation source achieves 2 μm resolution (at 6W) by adopting a diamond window transmission target, and is an X-ray source for industrial non-destructive inspection that enables high-resolution and high-speed imaging.
Components
Features
- 110 kV voltage ramp time within 1 s.
・Quick image acquisition - Maintenance-free target
・No need for target rotation
・Improving equipment operation ratio - Warming-up within 3 min.
・Solution of the long waiting time at starting up X-ray equipment
・No need for tube aging after long term storage - Self-diagnosis of X-ray tube lifetime
・Scheduled maintenance of X-ray equipment - CE and RoHS compliant
・Applicable for overseas operation - Hardware pulse option available, Please contact for details
♦Image examples
Bonding wire
Multi Layer Ceramic Capacitor
Carbon fiver
Bonding wire
Void
Ant
* High resolution data and photographing conditions of the images are available. Please inquire with this form.
Applications
Widely applicable for industry of non-destructive Inspection.
- X-ray radioscopy
- X-ray CT
- Offline analysis
Notice :
The X-ray sources were developed specifically for industrial use and can not be used for food and drinks or medical applications.
Specifications
Parameter | Unit | G-511VL-D | G-511VL-DP |
---|---|---|---|
Tube Voltage Operational Range | kV | 40 - 110 | |
Maximum Output | W | 10 | |
Tube Current Operational Range (Target Current) |
µA | 10 - 100 | |
Minimum Resolution (JIMA RT RC-02B) |
µm | 2 | |
X-ray Window Material | — | Diamond | |
Focus-to-Object Distance (FOD) | mm | Minimum 0.29 | |
Target Material | — | Tungsten | |
X-ray Beam Angle | deg. | 168 (Max.), 80 (80%, Equidistance) | |
Weight | kg | 21 | |
Operation | — | Continuous, Pulse | |
Pulse | — | Software≧1 s | Software≧1 s Hardtware≧50 ms |
External Control | — | RS-232C | |
Input Voltage (DC) | V | 24 (+1.2, -1.2) | |
Maximum Power Consumption | W | 40 | |
Operational Ambient Temperature | °C | 10 - 45 | |
Storage Temperature | °C | 0 - 50 | |
Operational and Storage Humidity | % | ≦85 (No Condensation) | |
High Voltage Power Supply | — | Built-in | |
Conformity | — | CE marking, RoHS |